Providing the Shaver socket is reduced to 110V it should go in zone 2 or preferably, zone 3, never in zone 1. Also it’s worthy to note that there should be no 240V sockets in the bathroom at all.
Can a shaver socket be fitted in Zone 2?
According to the updated 17th edition of the IEE Wiring Regulations, it is safe to install electric shaver sockets in your bathroom providing the socket is 110v and installed in zone 2 or beyond, with at least a 3-metre gap from either the bath or shower. This is done to avoid any splash backs onto the socket.
Can shaver socket go in Zone 1?
Shaver sockets are becoming a common feature in bathrooms, whether they are directly installed into the wall, or they come as a feature in a mirrored cabinet. In relation to bathroom zones, shaver socket regulations state that one must be placed at least 3m horizontally from the boundary of zone 1.
Can you run a shaver socket off a ring main?
Yes of course you can run a shaver socket from a ring final with no FCU in between.
Are shaver sockets IP rated?
Shaver Sockets are not IP rated, but they are a special case as described above. Devices that can be used in bathrooms need to be low Voltage and in terms of this there are two classes: PELV – Protective Extra Low Voltage: These are devices which are connected to earth via the transformer.
Where can you put a Shaver socket?
Providing the Shaver socket is reduced to 110V it should go in zone 2 or preferably, zone 3, never in zone 1. Also it’s worthy to note that there should be no 240V sockets in the bathroom at all.
Are Shaver sockets SELV or Pelv?
SELV is general used for single items. Shaver socket, down lights with transformers, door bells, bathroom fans, etc. PELV is more for distributed systems or circuits which include multiple items of equipment.
Can IPX4 be used in Zone 1?
The area stretching 0.6m outside the perimeter of the bath to a height of 2.25m. As with Zone 1, the minimum rating for this zone is IPX4.
Can you put a 230V fan in Zone 1?
230V ventilation gear is allowable in zone 1 as long as it is at least IP44 and the manufacturers instructions don’t state that it isn’t suitable for use in zone 1.
What can you plug into a shaver socket?
With it came a new connector. Hence the 2 pin plug you find on the charging stands for electric toothbrushes and to power other things like electric shavers, which are most commonly used in the bathroom. These sockets are often known as ‘shaver sockets’ because this is what is commonly connected into them.
Does a shaver socket need an RCD?
An RCD offers no additional protection for a shaver socket. The shaver socket has a transformer inside and the secondary winding is isolated from earth.
Does a shaver socket need an isolator?
The shaver socket does not need an isolator. 2. The fan need to be of a low voltage type, the isolator and transformer are fitted outside the bathroom, the isolator is normally placed above the door and often the transformer in the loft.
Can I spur off a shaver socket?
A shaver socket must only supply one item. If there are two outlets they both must have their own isolated windings. They are type tested and it is not permissible to alter them and although it would seem safer to have the transformer remote from socket it is not allowed.
Why is a shaver socket allowed in a bathroom?
1 Answer. UK shaver sockets are not a lower voltage, but the ones in bathrooms include an isolating transformer and thermal cutout so that neither wire of the shaver has any voltage to earth (so a shock to earth is impossible) and the socket cannot be used for more powerful appliances.
Can IP65 be used in a shower?
Zone 1 is the area above the bath or shower to a height of 2.25m from the floor. In this zone a minimum rating of IP45 is required but it is generally accepted that IP65 is to be used. It’s also worth noting that most shower lights are rated at IP65 in any case.
Can IP44 be used in bathroom?
IP44 lighting is suitable for use in Zone 2 and Zone 3 (Outside Zones) – in other words, within 60cm from the edge of the bath and to a height of 2.25m from the floor.